WF 3169 Battery Stack Monitor Module

WF 3169 Battery Stack Monitor Module

Is the sample rate specified for full configuration?
Answer: Yes, it is.  The specified rate of 235 Hz means that all 24 channels will be sampled 235 times per second. So you will get 24 measurement values ev...
Thu, 9 Jul, 2020 at 11:47 AM
Are all measurements taken simultaneously?
Answer: No, there is is a set of four multiplexers and ADC’s in the hardware that scans the inputs in groups of four with an offset of six channels. Fir...
Thu, 9 Jul, 2020 at 12:55 PM