If you don't have enough battery cells to fill all the channels of the module you will have to put jumpers (a short length of conductor used to close circuit) between each unconnected channel.

Example:
If you have 6 battery cells and have filled them from COM-C5, you will have to put jumpers between all of the remaining unconnected channels (C5-C6, C6-C7).